Ecodesign requirements for CE models

Table 1. Ecodesign requirements and data
Ecodesign requirement Idle With load Description
Output current 300.88 A Measured at the rated duty cycle for the system at the highest output power.
Output voltage 222.94 V
Output active power 67.05 kW
Root Mean Square (RMS) of the supply voltage 401.35 V 398.65 V Measured at idle state and at the rated duty cycle for the system at the highest output power.
Supply active power 40.1 W 73.08 W
Total harmonic distortion of the supply voltage (UTHD) 1.15% 5.72%
Idle state power consumption by the power source 40.1 W Measured at idle state. 1
Efficiency 91.75% Calculated at the rated duty cycle for the system at the highest output power.
1 External devices were disconnected during idle measurement.