Remove the power from the cutting system

Many maintenance procedures require you to remove the power from the cutting system. To do this safely, use this procedure.

Before you remove the power from the cutting system, it can be helpful to move the torch to the edge of the cutting table and raise the torch lifter to its highest point. This provides easier access to the torch and consumable parts.

  1. Set the line-disconnect switch to the OFF position.
  2. If the cutting system is not hard wired, disconnect the main power from the electric power.

    If the cutting system is hard wired, you cannot disconnect the main power from the electric power.

    Even if you remove the power from the cutting system, you can still get a serious electric shock if the plasma power supply remains connected to an electric power source. Use extreme care during service and maintenance when the cutting system is connected to electricity.

  3. Make sure that the power-indicator Light Emitting Diode (LED) is not illuminated on the plasma power supply, gas connect console, or torch connect console.