Distance requirements for ventilation and access

Make sure that all system components have sufficient open space around them for ventilation and service access.

Requirements for ventilation

  • Do not cause blockages near ventilation louvers on the corners or bottom panels of the front and rear of the plasma power supply. A separation distance of least 1 m (3.3 feet) is required for ventilation.
  • Do not cause blockages near the fan inlet grates on the front of the cooler or the rear ventilation louvers on the rear of the cooler. A separation distance of least 1 m (3.3 feet) is required for ventilation.
  • Do not cause blockages near the ventilation louvers on the gas connect console. A separation distance of least 1.27 cm (0.50 inch) is required for ventilation.
  • Do not cause blockages near the ventilation louvers on the TorchConnect console. You must use the mounting brackets to allow space between the console and mounting surface.

Requirements for service and maintenance access

Hypertherm® recommends a minimum distance of 1 meter (3.3 feet) between the plasma power supply, the cooler, and other system components, or between the plasma power supply, the cooler, and an obstacle.