Worksite requirements for system components
Use the following recommendations to put the plasma power supply in the best position:
- Level surface (less than 10° incline)
- Clean and dry area
- Able to support at least 782.4 kg (1,725 lb)
- With a minimum distance of 1 meter (3.3 feet) between the plasma power supply and other system components, or between the plasma power supply and an obstacle.
Use the following recommendations to put the cooler in the best position:
- Level surface (less than 10° incline)
- Clean and dry area
- Able to support at least 90.72 kg (200 lb)
- With a minimum distance of 1 meter (3.3 feet) between the cooler and other system components, or between the cooler and an obstacle.
Use the following recommendations to put the gas connect console in the best position:
- Level surface (less than 10° incline)
- Clean and dry area
- Able to support the weight of your gas connect console. Refer to Gas connect console specifications.
Use the following recommendations to put the TorchConnect™ console in the best position:
- Clean and dry area
- Able to support at least 9.3 kg (20.5 lb)
Note:
These recommendations for the gas connect console and the TorchConnect console are also applicable for mezzanine locations.