Ecodesign requirements for CE models

Table 1. Ecodesign requirements and data
Ecodesign requirement Idle With load Description
Output current – 460.86 A Measured at the rated duty cycle for the system at the highest output power.
Output voltage – 222.59 VDC
Output active power – 102.53 kW
Root Mean Square (RMS) of the supply voltage 405.80 VAC 401.85 VAC Measured at idle state and at the rated duty cycle for the system at the highest output power.
Supply active power 34 W 110.44 kW
Total harmonic distortion of the supply voltage (UTHD) 1.16% 7.04%
Idle state power consumption by the power source 34 W – Measured at idle state. 1
Efficiency – 92.84% Calculated at the rated duty cycle for the system at the highest output power.
1 External devices were disconnected during idle measurement.