The system changes the gas pressure after you set it manually

The plasma power supply will override manual gas mode under some conditions.

One of these conditions caused the gas pressure to be changed

  • You installed a different type of Hypertherm® cartridge.
  • You adjusted the gas pressure before you unlocked the torch.
  • You enabled "marking mode" by adjusting the amperage to be less than 20 A with a FineCut® Hypertherm cartridge installed on the torch.
  1. Make sure that the torch-lock switch is in the green "ready to fire" position.
  2. Set the amperage to be more than 20 A.
  3. Manually adjust the gas pressure as necessary.

    The selected cut mode Light Emitting Diode (LED) on the front panel flashes while the gas pressure is manually set.