Hypertherm plasma power supply ratings
| Rated open-circuit voltage (U0) |
200 V – 240 V, CSA/CE/CCC 400 V, CE/CCC 480 V, CSA |
275 VDC 265 VDC 275 VDC |
|
|---|---|---|---|
| Output characteristic1 | Drooping | ||
| Rated output current (I2) | 9 A – 45 A2 | ||
| Rated output voltage (U2) | 155 VDC | ||
| Duty cycle at 40°C (104°F)3 |
50% at 45 A (I2) / 155 VDC (U2) 60% at 41 A (I2) / 155 VDC (U2) 100% at 32 A (I2) / 155 VDC (U2) |
||
| Operating temperature | -10°C – 40°C (14°F – 104°F) | ||
| Storage temperature | -25°C – 55°C (-13°F – 131°F) | ||
| Power factor |
200 V - 240 V, 1-phase, CSA/CE/CCC 400 V, 3-phase, CE/CCC 480 V, 3-phase, CSA |
0.99 0.94 0.93 |
|
|
Idle state power consumption (CE models) |
230 V 400 V |
17 W 23 W |
|
| Power source efficiency at rated maximum output power (CE models) |
230 V 400 V |
90.3% 89.9% |
|
| Rsce – Short Circuit Ratio (CE models only) |
U1 - Volts AC rms, 3-phase 400 V, CE |
Rsce 73 |
|
| Electromagnetic Compatibility (EMC) emissions classification CISPR 11 (CE models only)4 | Class A | ||
| Input voltage (U1) / Input current (I1) at rated output (U2 MAX I2 MAX) |
CSA (50 Hz/60Hz) 1-Phase:
3-Phase:
|
CE/CCC (50 Hz/60 Hz) 1-phase 5 , 6
3-phase 4, 7
|
|
| Gas type | Air | Nitrogen (N2) | F5 8 |
| Gas quality | Clean, dry, oil-free per ISO 8573-1 Class 1.2.2 |
99.95% pure Clean, dry, oil-free |
99.98% pure (F5 = 95% nitrogen [N2], 5% hydrogen [H]) |
| Recommended gas inlet flow rate/pressure | Cutting | 212 slpm at 5.9 bar (450 scfh at 85 psi) | |
| Maximum removal gouging | 212 slpm at 4.8 bar (450 scfh at 70 psi) | ||
| Marking | 142 slpm at 4.1 bar (300 scfh at 60 psi) | ||
1 Defined as a plot of output voltage
versus output current. 2 An output current
setting of 9 A to 19 A is reserved for marking, and is only
available when a FineCut®
Hypertherm® cartridge is
installed on the torch. 3 Refer to the data plate on the
bottom of the plasma power supply for more information about
duty cycle and for International Electrotechnical Commission (IEC)
ratings. 4 NOTICE: This
Class A equipment is not intended for use in residential
locations where the public low voltage supply system supplies
the electrical power. It is not always easy to supply
electromagnetic compatibility in those locations, because of
conducted and radiated disturbances. 5 This product meets the technical requirements of
IEC 61000-3-3 and is
not subject to conditional connection. 6 Equipment
complies with IEC
61000-3-12. 7 Equipment complies with IEC 61000-3-12 if the
Short-circuit power (Ssc)
is greater than or equal to 1003 KVA at the interface point
between the operator’s supply and the public system. The
installer or user of the equipment must consult with the
distribution network operator, if necessary, to ensure that the
equipment is connected only to an
electric
power
source
with a
Ssc
greater than or equal to 1003 KVA. 8 F5 is only recommended to cut stainless
steel. | |||