Install a remote on-off switch
As an alternative to using the main power supply, do these steps to install your own remote on-off switch so that you can control power to the gas connect console, TorchConnect™ console, and other parts.
| Warning | |
|---|---|
When the remote on-off switch is set to OFF (disabled), electric power stays ON
(active) to the following parts:
- Power-indicator Light Emitting Diode (LED) on the front of the plasma power supply
- Control Printed Circuit Board (PCB)
- Control transformer (can be different on input and output)
- Input to the relay that controls the 48 V power supply
- 24 V power supply
- 120 V to the input side of the contactor or contactors
- 120 VAC
- 220 VAC on the power distribution PCB
- 120 VAC to the input side of the 40 V power relay
- 220 VAC to the input side of the cooler power relay