Troubleshooting for low fan speeds – HXFAN
Diagnostic codes 748 and 749
Diagnostic codes 748 and 749 occur when a heat exchanger fan is under performing.
Note:
For XPR170™ and XPR300™, the heat exchanger fans are in the plasma power supply. For XPR460™, the heat exchanger fans are in the cooler.
Symptoms
| Code | Symptoms | XPR® models | XPR action | Code cancels with... |
|---|---|---|---|---|
| 748 | The fan tachometer feedback for HXFAN 1 is less than the minimum acceptable value. | All models | None |
|
| 749 | The fan tachometer feedback for HXFAN 2 is less than the minimum acceptable value. | XPR300, XPR460 |
Corrective action
- Use the Fan diagnostic codes diagram to identify the location of the HXFAN in the cooler.
-
Make sure that the following fan connections are good, and tighten loose
connections if found:
- The fan connector
- The wiring to J2 on the cooler fan power distribution Printed Circuit Board (PCB) (PCB 3 in the cooler)
- The wiring to J3.3 (HXFAN 1) and J4 (HXFAN 2) on the cooler fan power distribution PCB (PCB 3 in the cooler)
- The wiring to J5 on the cooler control PCB (PCB 2 in the cooler)
- Examine the power output of the 48 VDC power source that is in the cooler.
- If the power output is not correct, replace the 48 VDC power source.
- Examine the solid-state relay, and make sure that it is operating correctly.
- If you do not find any loose connections and the 48 VDC power source and solid-state relay are good, replace the fan.