Troubleshooting for invalid processes
Diagnostic code 716
Diagnostic code 716 occurs when there is a problem with the cut process sent to the Computer Numerical Control (CNC). There are six different smart-fault data values that you can get with a 716 code. The troubleshooting steps are different for the different values. When you get a 716 code, make sure that you identify the smart-fault value before you send a process change.
For an overview of the troubleshooting process for the 716 code, refer to Troubleshooting flowchart for diagnostic code 716.
Symptoms
| Code | Symptoms | XPR® models | XPR action | Code cancels with... |
|---|---|---|---|---|
| 716 |
The operator-selected process is not supported by this plasma cutting system. There are six smart-fault data values for the 716 code:
|
All models | None |
|
1: invalid id
The process ID is equal to zero (0).
Select a process ID for the application. Refer to the XPR Cut Charts Instruction Manual (809830).
2: invalid user
Another interface has control of the cutting system.
- Serial
- EtherCAT®
- Wireless
3: invalid user source
Another interface has control of the cutting system.
Only one wireless interface at a time can send a process ID to the plasma cutting system.
Select or change the interface that has control of the plasma cutting system. Refer to Change the device that has control.
If the CNC has control and you change control to another device using the RESET OPERATOR button in the XPR web interface, you can get a 716 code if you try to send a process from the CNC. If this occurs, select RESET OPERATOR again on the same device as before to give control back to the CNC. In some conditions, it can also be necessary to set the line-disconnect switch to OFF and then back to ON.
4: invalid process
An incorrect process ID was sent.
Select the correct process ID for the application. Refer to the XPR Cut Charts Instruction Manual (809830).
5: not allowed or system not ready
- Initial Checks state (2)
- Inert Gas Purge state (4)
- Wait for Start state (5)
- Manual Leak Test state (20)
- End of Cycle state (14)
6: not supported
The different gas connect consoles have different capabilities. For example, argon assist and argon marking for mild steel are available for cutting systems installed with OptiMix™, VWI™, or CorePlus™ gas connect consoles, but not with Core™.