Diagnostic code 777
Diagnostic code 777 occurs when there is a fault related to the pilot relay.
Symptoms
| Code |
Symptoms |
XPR® models |
XPR action |
Code cancels with... |
| 777 |
The pilot-relay driver finds an overcurrent
condition. |
All models |
None |
- Set process
- Remote on-off
|
Safety consideration for the XPR460
Corrective action
-
Remove the power from the cutting
system.
-
Remove the control-side panel from the plasma power supply.
-
Examine the control Printed Circuit Board (PCB) (PCB 1)
in the plasma power supply.
-
Disconnect J6 from the control PCB.
-
Remove the cover from the pilot-arc relay.
-
Use an ohmmeter to measure the coil resistance across wire 21 and wire
22.
Look for a resistance of approximately 280 ohms (Ω).
-
If the ohms value is more than 10% higher or lower than 280 ohms (Ω),
replace the pilot-arc relay.
-
If the ohms value is in the permitted range, make sure that you have
the most recent XPR
firmware.