Coolant requirements for operation between -10°C – 40°C (14°F – 104°F)

Use the Hypertherm® premixed coolant for the usual operating temperature range for plasma cutting systems. Adjust the coolant mix to operate the system at temperatures that are colder than -10°C (14°F).

Use Hypertherm premixed coolant (028872) when operating in a temperature range of -10°C – 40°C (14°F – 104°F).

Note:

If you use shield water, the temperature range for cutting system operation and storage is reduced to 0°C – 40°C (32°F – 104°F).

If it is possible for the temperature to go below -10°C (14°F) when the cutting system is not in use, adjust coolant propylene glycol concentration to 50% to prevent damage to cooling system components.

Note:

Operating your plasma cutting system below -10°C (14°F) is not recommended due to reduced consumable life and performance.

To increase the coolant propylene glycol percentage, add 100% propylene glycol (028873) to the premixed Hypertherm coolant (028872) according to the following calculation. The maximum percentage of propylene glycol should never exceed 50%. Also refer to Make an estimate of the total coolant volume.

Table 1. Calculate the correct quantity of propylene glycol
Total system coolant volume (in liters) X 0.4 = Total volume in liters of 100% propylene glycol to add
Total system coolant volume (in U.S. gallons) X 0.4 = Total volume in U.S. gallons of 100% propylene glycol to add