Example of external ohmic contact sense

Refer to this example diagram if it is necessary to change the wiring inside of the TorchConnect™ console so that you can use external ohmic contact sense.

Figure 1. Example diagram of external ohmic contact sense
This image shows an example of external ohmic contact sense.
1 Torch
2 Ohmic wire, inside of torch and torch lead
3 TorchConnect console
4 Ohmic wire, torch receptacle to ohmic relay
5 Ohmic relay
6 Ohmic wire, ohmic relay to J4
7 Ohmic Printed Circuit Board (PCB)
8 Ohmic wire, J4 to torch lifter or third-party ohmic circuit: pin 1 and pin 2 are connected in the ohmic PCB
9 Torch lifter or third-party ohmic circuit
10 Controller Area Network (CAN) connection
11 Ohmic wire, J4 to torch lifter or third-party ohmic circuit: pin 1 and pin 2 are connected in the ohmic PCB, one ground connection (mandatory)
12 Torch lifter or third-party ohmic circuit