Example of external ohmic contact sense

Refer to this example diagram if it is necessary to change the wiring inside of the TorchConnect console so that you can use external ohmic contact sense.

Figure 1. Example diagram of external ohmic contact sense
This image shows an example of external ohmic contact sense.
1 Torch
2 Ohmic wire, inside of torch and torch lead
3 TorchConnect console
4 Ohmic wire, torch receptacle to ohmic relay
5 Ohmic relay
6 Ohmic wire, ohmic relay to J4
7 Ohmic Printed Circuit Board (PCB)
8 Ohmic wire, J4 to torch lifter or third-party ohmic circuit: pin 1 and pin 2 are connected in the ohmic PCB
9 Torch lifter or third-party ohmic circuit
10 Controller Area Network (CAN) connection
11 Ohmic wire, J4 to torch lifter or third-party ohmic circuit: pin 1 and pin 2 are connected in the ohmic PCB, one ground connection (mandatory)
12 Torch lifter or third-party ohmic circuit