Distance requirements for ventilation and access
Make sure that all system components have sufficient open space around them for ventilation and service access.
Requirements for ventilation
- Do not block the ventilation louvers on the corners or bottom panels of the front and back of the plasma power supply. A separation distance of least one m (3.3 feet) is required for ventilation.
- Do not block the ventilation louvers on the gas connect console. A separation distance of least 1.27 cm (0.50 inch) is required for ventilation.
- Do not block the ventilation louvers on the torch connect console. You must use the mounting brackets to allow space between the console and mounting surface.
Requirements for service and maintenance access
Hypertherm® recommends a minimum distance of one meter (3.3 feet) between the plasma power supply and other system components, or between the plasma power supply and an obstacle.