Power cord and plug requirements

Table 1. CSA systems
Model Configurations Power cord Power plug
1-phase 200 V – 240 V 10 AWG 3-wire

50 A, 250 V power plug (NEMA 6-50P) included

3-phase 480 V 14 AWG 4-wire Power plug not included 1
1 An approved plug must be installed on the power cord by a licensed electrician according to all national and local codes.
Table 2. CE/CCC systems
Model Configurations Power cord Power plug
1-phase 200 V – 240 V 10 AWG 3-wire Power plug not included 1
6 mm2 3-wire style H07RN-F 2
3-phase 380 V / 400 V 2.5 mm2 4-wire style H07RN-F3 Power plug not included
1 An approved plug must be installed on the power cord by a licensed electrician according to all national and local codes.
2 Style H07RN-F cord is a harmonized, heavy-duty, flexible, rubber-insulated, black-neoprene-jacketed multi-conductor IEC60245-4 / EN50525 European power cord with CE printed on the cord. The H07RN-F cord used by Hypertherm® also has a CCC certification to GB/T 5013.4, with CCC printed on the cord.