The system is not cutting at full cutting power, and the plasma arc does not time out after 5 seconds

The system is not connected to ground sufficiently. The output from the plasma power supply is too low.

The work lead connection is not satisfactory

  1. If possible, move the work clamp closer to the area of the workpiece you are cutting.
  2. Clean the area where the work clamp comes into contact with the workpiece or cutting table, and remove rust, paint, or other residue.
  3. Make sure that the cutting table is correctly grounded and has good contact with the workpiece.
  4. Examine the work lead for a loose connection at the plasma power supply and at the work clamp.
  5. Examine the work clamp, and repair or replace the clamp if necessary.
  6. Examine the work lead, and repair or replace the lead if necessary.

The work lead has damage

Measure the resistance across the work lead at J23 on the power Printed Circuit Board (PCB). If the resistance is greater than 5 ohms (Ω), repair or replace the work lead.

The output current is set too low

Use the adjustment knob to increase the output current (A) as necessary.

The power PCB is defective

It is possible that a sensor on the power PCB is defective, or a component on the power PCB is short-circuited.

  • Replace the power PCB if necessary.