Reset the wireless module
It is possible to make mistakes when you set up the wireless module. Use this procedure to set your wireless module to its default settings.
| Warning | |
|---|---|
ELECTRIC SHOCK CAN KILL
The plasma power supply contains dangerous electric voltages that can
seriously injure or kill you. Even if the plasma power supply is turned OFF, you
can still get a serious electric shock if the plasma power supply remains
connected to an electric power source.
Use extreme caution if you do diagnosis or maintenance tasks when the
plasma power supply remains connected to an electric power source and the outer
cover or panels are removed. All work that requires removal of the plasma power
supply outer cover or panels must be done by a qualified technician. Refer to
the Safety and Compliance Manual (80669C) for more safety
information.
| |
| Warning | |
|---|---|
ELECTRIC SHOCK CAN KILL
The plasma power supply contains dangerous electric voltages that can
seriously injure or kill you. Even if the plasma power supply is turned OFF, you
can still get a serious electric shock if the plasma power supply remains
connected to an electric power source.
Use extreme caution if you do diagnosis or maintenance tasks when the
plasma power supply remains connected to an electric power source and the outer
cover or panels are removed.
| |
-
Remove the power from the cutting system:
- Set the line-disconnect switch to the OFF position.
- Make sure that the power-indicator Light Emitting Diode (LED) on the plasma power supply is not illuminated.
- Remove the control-side panel of the plasma power supply.
-
On the main control Printed Circuit Board (PCB), set position 4
on DIP switch S3 to the ON position.
This disables the wireless connection.
-
Supply power to the cutting system:
- Set the line-disconnect switch to the ON position.
- Make sure that the power-indicator LED on the plasma power supply is illuminated.
Warning ELECTRIC SHOCK CAN KILLThe plasma power supply contains dangerous electric voltages that can seriously injure or kill you.Use extreme caution if you do service or maintenance work on a plasma power supply when it is connected to an electric power source and the outer cover or panels are removed. - Wait 30 seconds.
-
Remove the power from the cutting system:
- Set the line-disconnect switch to the OFF position.
- Make sure that the power-indicator LED on the plasma power supply is not illuminated.
-
On the main control PCB, set position 4
on DIP switch S3 to the OFF position.
This enables the wireless connection.
- Install the control-side panel of the plasma power supply.
-
Supply power to the cutting system:
- Set the line-disconnect switch to the ON position.
- Make sure that the power-indicator LED on the plasma power supply is illuminated.
-
Wait
60
seconds.
The wireless module is now set to the factory default settings.