Troubleshooting for torch connection faults (0-52-0)

The system usually shows a 0-52-0 fault code as an indication that the torch is not connected to the plasma power supply.

Fault codes and fault LEDs

Fault code Fault LEDs Torch LED Description Stops the system from operating?
0-52-0 The image shows the Torch Fault Light Emitting Diode.

ON

The image shows the general fault Light Emitting Diode.

ON

The image shows the Power ONLight Emitting Diode.

ON

The image shows the Torch Light Emitting Diode when it is off.

None

The torch is not connected. Yes
If you disconnect the torch while the plasma power supply is set to ON (I), you get the 0-52-0 fault code.
If you disconnect the torch while the plasma power supply is set to OFF (O), you get the 0-50-0 fault code the next time you set the plasma power supply to ON (I).

Corrective action for 0-52-0 faults

  1. Make sure that the torch lead is correctly connected to the FastConnect receptacle on the front of the plasma power supply.
  2. Do a quick restart.