Troubleshooting for remote controller faults (0-11-n)
A 0-11-n fault code identifies a problem with the remote controller. There can also be a problem with the software interface to the system. The system cannot interpret the operating mode, output current, or gas pressure information coming from the controller.
Fault codes and fault LEDs
| Fault code | Fault LEDs | Torch LED | Description | Stops the system from operating? |
|---|---|---|---|---|
| 0-11-0 |
ON |
Computer Numerical Control (CNC) use only |
The remote control operating mode is incorrect or not permitted for the installed Hypertherm® cartridge. The permitted operating modes for Hypertherm cutting cartridges is 1 (Cut mode). The permitted operating mode for a Hypertherm gouging cartridge is 2 (Gouge mode). |
No. These fault codes only apply to remotely controlled plasma power supplies. |
| 0-11-1 |
The permitted operating modes for Hypertherm cutting cartridges is 1 (Cut mode). The permitted operating mode for a Hypertherm gouging cartridge is 2 (Gouge mode). The permitted values relate to the minimum and maximum output current (A) for the plasma power supply and the installed Hypertherm cartridge. |
|||
| 0-11-2 |
The remote control gas pressure is incorrect or not permitted. The permitted gas pressure relates to the selected process and operating mode, and to the installed torch, torch lead, and Hypertherm cartridge. |