Operational faults

An operational fault code can be for a notification or for a condition that stops the cutting process. Hypertherm® recommends that you do the steps for all faults that occur. Troubleshooting all faults helps you to get optimal cut quality and consumable life.

A label with descriptions for many common fault codes is included with the system. Put the label on the plasma power supply or near your work area for reference.

Fault code Fault LEDs Torch LED Description
None The image shows the Power ON Light Emitting Diode flashing.

Flashes

The image shows the torch Light Emitting Diode illuminated yellow.

Yellow

None The image shows the Gas Pressure fault Light Emitting Diode.

ON

The image shows the System Fault Light Emitting Diode.

ON

The image shows the torch Light Emitting Diode illuminated yellow.

Yellow

None The image shows the Gas Pressure fault Light Emitting Diode flashing.

Flashes quickly

The image shows the torch Light Emitting Diode illuminated yellow.

Yellow

None The image shows the Torch Fault Light Emitting Diode flashing.

Flashes slowly

The image shows the torch Light Emitting Diode illuminated yellow.

Yellow

None The image shows the Torch Fault Light Emitting Diode flashing.

Flashes quickly

None The image shows the Temperature fault Light Emitting Diode.

ON

The image shows the System Fault Light Emitting Diode.

ON

The image shows the torch Light Emitting Diode illuminated yellow.

Yellow

None The image shows the Torch Cap fault Light Emitting Diode.

ON

The image shows the torch Light Emitting Diode illuminated yellow.

Yellow

None The images shows the Temperature fault Light Emitting Diode flashing. The image shows the System Fault Light Emitting Diode flashing.

Flash alternately

The image shows the torch Light Emitting Diode illuminated yellow.

Yellow

None The image shows the Power ON Light Emitting Diode flashing.

Flashes

The image shows the System Fault Light Emitting Diode.

ON

The image shows the torch Light Emitting Diode illuminated yellow.

Yellow

None The image shows the Power ON Light Emitting Diode flashing.

Flashes

The image shows the torch Light Emitting Diode illuminated yellow.

Yellow

  • The AC input voltage is too low (>10% less than the rated voltage for 1-phase models or >15% less than the rated voltage for 3-phase models).
  • The AC input voltage is too high (>10% more than the rated voltage for 1-phase models or >15% more than the rated voltage for 3-phase models).
  • Refer to Troubleshooting for input voltage faults.
0-11-0 The image shows the Power ONLight Emitting Diode.

ON

Computer Numerical Control (CNC) use only
  • The remote control operating mode is incorrect or not permitted for the installed Hypertherm cartridge.
  • The permitted operating modes for Hypertherm cutting cartridges is 1 (Cut mode).
  • The permitted operating mode for a Hypertherm gouging cartridge is 2 (Gouge mode).
  • Refer to Troubleshooting for remote controller faults (0-11-n).
0-11-1
  • The remote control output current (A) is incorrect or not permitted for the installed Hypertherm cartridge.
  • The permitted values relate to the minimum and maximum output current (A) for the plasma power supply and the installed Hypertherm cartridge.
  • Refer to Troubleshooting for remote controller faults (0-11-n).
0-11-2
  • The remote control gas pressure is incorrect or not permitted.
  • The permitted gas pressure relates to the selected process and operating mode, and to the installed torch, torch lead, and Hypertherm cartridge.
  • Refer to Troubleshooting for remote controller faults (0-11-n).
0-12-1 The image shows the Power ONLight Emitting Diode.

ON

CNC use only
0-12-2
0-12-3
0-14-0 The image shows the System Fault Light Emitting Diode.

ON

The image shows the torch Light Emitting Diode illuminated yellow.

Flashes yellow

0-14-1 The image shows the Power ONLight Emitting Diode.
0-19-9 Only displays on a CNC or when you use the Hypertherm SYNC Cartridge Reader (528083) and app to read data from a Hypertherm cartridge.
0-40-5 The image shows the Temperature fault Light Emitting Diode.

ON

The image shows the torch Light Emitting Diode illuminated yellow.

Yellow

0-50-1 The image shows the Torch Cap fault Light Emitting Diode.

ON

The image shows the torch Light Emitting Diode illuminated yellow.

Yellow

0-50-2
0-50-3 The image shows the Power ONLight Emitting Diode.

ON

0-52-0 The image shows the Torch Cap fault Light Emitting Diode.

ON

The image shows the System Fault Light Emitting Diode.

ON

The image shows the torch Light Emitting Diode when off.

None

0-98-1 The image shows the System Fault Light Emitting Diode.

ON

The image shows the torch Light Emitting Diode illuminated yellow.

Yellow

0-98-2 The image shows the System Fault Light Emitting Diode.

ON

The image shows the torch Light Emitting Diode illuminated yellow.

Flashes yellow