Disable the wireless connection temporarily
If you want to disable the wireless connection temporarily, use this procedure.
| Warning | |
|---|---|
ELECTRIC SHOCK CAN KILL
The plasma power supply contains dangerous electric voltages that can
seriously injure or kill you. Even if the plasma power supply is turned OFF, you
can still get a serious electric shock if the plasma power supply remains
connected to an electric power source.
Use extreme caution if you do diagnosis or maintenance tasks when the
plasma power supply remains connected to an electric power source and the outer
cover or panels are removed. All work that requires removal of the plasma power
supply outer cover or panels must be done by a qualified technician. Refer to
the Safety and Compliance Manual (80669C) for more safety
information.
| |
-
Remove the power from the cutting system:
- Set the line-disconnect switch to the OFF position.
- Make sure that the power-indicator Light Emitting Diode (LED) on the plasma power supply is not illuminated.
- If used, make sure that the alternate 24 VDC power input is removed from the main control Printed Circuit Board (PCB).
- Remove the control-side panel of the plasma power supply.
-
On the main control PCB, set position 4
on DIP switch S3 to the ON position.
This disables the wireless.
- Install the control-side panel of the plasma power supply.
-
Supply power to the cutting system:
- Set the line-disconnect switch to the ON position.
- Make sure that the power-indicator LED on the plasma power supply is illuminated.
- If used, make sure that the alternate 24 VDC power input is supplied to the main control PCB.