Reset the wireless module
It is possible to make mistakes when you set up the wireless module. Use this procedure to set your wireless module to its default settings.
| Warning | |
|---|---|
ELECTRIC SHOCK CAN KILL
The plasma power supply contains dangerous electric voltages that can
seriously injure or kill you. Even if the plasma power supply is turned OFF, you
can still get a serious electric shock if the plasma power supply remains
connected to an electric power source.
Use extreme caution if you do diagnosis or maintenance tasks when the
plasma power supply remains connected to an electric power source and the outer
cover or panels are removed. All work that requires removal of the plasma power
supply outer cover or panels must be done by a qualified technician. Refer to
the Safety and Compliance Manual (80669C) for more safety
information.
| |
-
Remove the power from the cutting system:
- Set the line-disconnect switch to the OFF position.
- Make sure that the power-indicator Light Emitting Diode (LED) on the plasma power supply is not illuminated.
- If used, make sure that the alternate 24 VDC power input is removed from the main control Printed Circuit Board (PCB).
- Remove the control-side panel of the plasma power supply.
-
Set
position 4 on DIP switch S3 on the main control
PCB
to the ON position.
This disables the wireless connection.
- Install the control-side panel of the plasma power supply.
-
Supply power to the cutting system:
- Set the line-disconnect switch to the ON position.
- Make sure that the power-indicator LED on the plasma power supply is illuminated.
- If used, make sure that the alternate 24 VDC power input is supplied to the main control PCB.
- Wait one minute.
-
Remove the power from the cutting system:
- Set the line-disconnect switch to the OFF position.
- Make sure that the power-indicator LED on the plasma power supply is not illuminated.
- If used, make sure that the alternate 24 VDC power input is removed from the main control PCB.
-
Set
position 4 on DIP switch S3
on
the main control PCB
to the OFF position.
This enables the wireless connection.
- Install the control-side panel of the plasma power supply.
-
Supply power to the cutting system:
- Set the line-disconnect switch to the ON position.
- Make sure that the power-indicator LED on the plasma power supply is illuminated.
- If used, make sure that the alternate 24 VDC power input is supplied to the main control PCB.
- Wait two minutes.
The wireless module is now set to the factory-default settings.