Steady state (12)

During the Steady state (12), the system does a check for correct coolant flow rate, gas pressures, temperatures, and chopper currents. It also does a check for the Plasma Start signal to be removed for the selected process.

The Steady state (12) uses the process that was sent by the operator (piercing, marking, or cutting).

The image shows a flowchart of the process for the Steady state (12).

If the Steady state (12) completes correctly, the process continues with Ramp-down state (13).

Refer to Initial inspection steps for troubleshooting procedures.