Troubleshooting for an analog-to-digital converter fault (2-00-0)

A 2-00-0 system fault indicates that the analog-to-digital converter value is out of range.

Fault codes and fault LEDs

Fault code Fault LEDs Torch LED Description Stops the system from operating?
2-00-0

ON

Red

The Analog-to-Digital Converter (ADC) value is out of range. Yes

Corrective action for 2-00-0 faults

  1. Do a cold restart.

    In some conditions, a restart can remove the fault condition.

  2. Replace the power Printed Circuit Board (PCB).

    If restarting the plasma power supply does not remove the fault condition, it is possible that the power PCB must be replaced.