Troubleshooting for inverter module temperature sensor faults (2-10-n)

2-10-n faults could indicate that there is a problem with the power Printed Circuit Board (PCB).

Fault codes and fault LEDs

Fault code Fault LEDs Torch LED Description Stops the system from operating?
2-10-0

ON

Red

The inverter module temperature sensor is open. Yes
2-10-1 The inverter module temperature sensor short-circuited. Yes

Corrective action for 2-10-0 and 2-10-1 faults

  1. Do a cold restart.

    In some conditions, a restart can remove the fault condition.

  2. Replace the power PCB.

    If restarting the plasma power supply does not remove the fault condition, it is possible that the power PCB must be replaced.