Troubleshooting for inverter IGBT faults (3-51-1, 3-52-0)

3-51-1 or 3-52-0 fault codes indicate that there is a phase or short circuit problem with the inverter module.

Fault codes and fault LEDs

Fault code Fault LEDs Torch LED Description Stops the system from operating?
3-51-1

ON

Red

The inverter IGBT is starting in phase instead of 180° out of phase. Yes.
3-52-0 A short circuit caused high-current distortion in the inverter IGBT. This is sometimes referred to as a shoot-through. Yes.

Corrective action for 3-51-1 and 3-52-0 faults

  • Replace the power Printed Circuit Board (PCB) if necessary.