Remove the power switch (3-phase)
-
Complete the following procedures:
- Set the power switch to OFF (O), disconnect the power cord from the power source, and disconnect the gas supply.
- Remove the plasma power supply cover and handle.
- Loosen the front panel.
- Remove the nut that secures the front panel power switch knob to the front panel.
- Push the knob out from the rear of the panel.
- Loosen the screws on the power switch assembly to remove the 6 wires.