Install the EMI PCB

  1. Place the new Electromagnetic Interference (EMI) Printed Circuit Board (PCB) into position at the location marked "EMI BOARD" on the center panel.

    Make sure the screw holes align and the placement pin aligns with the PCB.

  2. Secure the PCB to the center panel with 2 screws.

    Tighten the screws to 1.7 N∙m (15 lbf·in).

  3. Connect the 4 power wires.

    Tighten the screws to 2.3 N∙m (20 lbf·in).

    1. Brown wire (BRN) from the power switch to the top right terminal.
    2. Blue wire (BLU) from the power switch to the bottom right terminal.
    3. Brown wire (BRN) from the power cord to the top left terminal.
    4. Blue wire (BLU) from the power cord to the bottom left terminal.
  4. Slide the 4 insulating covers back into place over the power wire screws.
  5. Complete the following procedures:
    1. Install the component barrier.
    2. Install the plasma power supply cover and handle.
    3. Reconnect the gas supply.
    4. Reconnect the power cord.