Make sure that the torch is correctly installed in the torch receptacle.
Figure 1. Torch receptacle connections
| 1 |
Pilot arc |
| 2 |
Coolant return |
| 3 |
Ohmic |
| 4 |
Shield gas |
| 5 |
Coolant supply |
| 6 |
Plasma gas |
-
Apply a thin layer of silicone lubricant to the four O-rings that are
in
the torch body.
Do not apply silicone to the brass electrical connectors.
Make sure that the O-rings are shiny. However, too much lubricant can prevent
gas flow. Remove unwanted lubricant if found.
-
Install the torch in the torch receptacle:
-
Turn the torch body up with light force until you feel
the
torch
body
engage into position in the
torch
receptacle.
-
Use your hands to tighten the torch-coupler nut until the coupler nut
cannot turn.
Do not use
tools
to tighten the torch-coupler nut.
-
Make sure that the torch body is fully installed in the torch
receptacle
and that there is no space between the torch body and torch
receptacle.