Remove the torch and consumable parts
It can be necessary to remove the torch and consumable parts for replacement, maintenance, or troubleshooting.
| Warning | |
|---|---|
ELECTRIC SHOCK CAN KILL
Disconnect electric power before doing installation or maintenance. The
line-disconnect switch must STAY in the OFF position until all of the
installation or maintenance steps are complete. Refer to the Safety and
Compliance Manual (80669C) for more safety information.
| |
| Warning | |
|---|---|
HOT PARTS CAN CAUSE SEVERE BURNS
Let the temperature of the plasma power supply decrease before you do
any maintenance.
| |
| Notice | |
|---|---|
A LOOSE OR OVERTIGHTENED ELECTRODE CAN CAUSE DAMAGE TO THE
TORCH
If you do not correctly install and tighten the electrode, torch damage can
occur.
A tool is necessary to correctly install and tighten the torch electrode. Do not
use your hands. Hypertherm® recommends tightening the
electrode to a torque value of 2.3 N∙m – 2.8 N∙m (20 lbf∙in – 25 lbf∙in).
| |
-
Remove the power from the cutting system:
- Set the line-disconnect switch to the OFF position.
- Make sure that the power-indicator Light Emitting Diode (LED) is not illuminated on the plasma power supply or other system components.
-
Loosen the torch coupler nut to release the torch from the torch
receptacle.
The torch and consumable parts can be hot. Put on gloves to prevent burns.
-
Put the torch and torch receptacle on a surface that is:
- Clean
- Dry
- Oil-free
-
Remove the
consumable
parts as
shown:
- Use your hands to pull and twist off the swirl ring.
- Use the consumable-parts tool to turn the electrode counterclockwise.
- Hold the tool tightly and pull straight out to correctly remove the electrode.
-
Put the
consumable
parts on a surface that is:
- Clean
- Dry
- Oil-free