Diagnostic code 622
Diagnostic code 622 occurs when the Direct Current (DC) bus
voltage is too low.
Symptoms
| Code |
Symptoms |
XPR® models |
XPR action |
Code cancels with... |
| 622 |
The DC bus voltage is less than
280.5
V. |
All models |
Shut down |
Remote on-off |
Corrective action
-
Make sure that the input-line voltage is within ±14% of nominal.
-
Remove the power from the cutting
system.
-
Remove the cover from the contactor.
-
Examine the contacts for excess wear, and replace the contactor if
there is excess wear.
-
Examine the following contactor components for loose connections:
-
Contactor
-
Input to the chopper
-
Power cord
-
Tighten loose connections if found.
-
Examine the connections from the control Printed Circuit Board (PCB) on J6:
-
Look for loose or bad connections on pin 5 and pin 6.
-
Tighten loose connections, or replace bad connections.
-
Make sure that Light Emitting Diode (LED) D1 on the
power distribution PCB is
illuminated.
-
If D1 is not illuminated, examine the power distribution
PCB for:
-
120 VAC at the input (J1 pin 5 and pin 6)
-
Continuity on fuse FH2 (with power OFF)
-
120 VAC at the output (J5 pin 7, pin 8, pin 9, and pin
10)
-
If 120 VAC is not present on the J5 contactor output pins, examine the
J4 and K1 relay connections for damage.
-
If K1 is bad, replace either the power distribution PCB or the K1 relay (003257).
-
If you cannot find
or correct the problem, speak to your cutting machine supplier or regional Hypertherm® Technical Service team.