Troubleshooting for low fan speeds – CTRLFAN 2
Diagnostic code 751
Diagnostic code 751 occurs when the CTRLFAN 2 fan is not operating to specifications.
Symptoms
| Code | Symptoms | XPR® models | XPR action | Code cancels with... |
|---|---|---|---|---|
| 751 | The fan speed for CTRLFAN 2 is less than the minimum acceptable Revolutions Per Minute (RPM) value. | XPR170®, XPR300® | None |
|
Corrective action
- Use the Fan diagnostic codes diagram to identify the location of CTRLFAN 2 in the plasma power supply.
-
Make sure that the following fan connections are good, and tighten
loose connections if found:
- The fan connector
- The wiring to J8 on the fan power distribution Printed Circuit Board (PCB)
- The wiring to J7 on the control PCB
- Examine the 48 VDC power source output.
- If the power output is not correct, replace the 48 VDC power source.
- If you do not find any loose connections and the 48 VDC power source is good, replace the fan.