Troubleshooting for low fan speeds – CTRLFAN 1 / CAB FAN 1
Diagnostic codes 747 and 750
XPR170® and XPR300®: Diagnostic code 750 occurs when the CTRLFAN 1 fan is not operating to specifications.
XPR460®: Diagnostic code 747 occurs when the CAB FAN 1 fan is not operating to specifications.
Symptoms
| Code | Symptoms | XPR® models | XPR action | Code cancels with... |
|---|---|---|---|---|
| 747 | The fan speed for CAB FAN 1 is less than the minimum acceptable Revolutions Per Minute (RPM) value. | XPR460 | None |
|
| 750 | The fan speed for CTRLFAN 1 is less than the minimum acceptable RPM value. | XPR170, XPR300 |
Corrective action
- Use the Fan diagnostic codes diagram to identify the location of CTRLFAN 1 (XPR170, XPR300) or CAB FAN 1 (XPR460) in the plasma power supply.
-
Make sure that the following fan connections are good, and tighten
loose connections if found:
- The fan connector
- The wiring to J7 on the fan power distribution Printed Circuit Board (PCB)
- The wiring to J7 on the control PCB
- Tighten loose connections if found.
- Examine the 48 VDC power source output.
- If the power output is not correct, replace the 48 VDC power source.
- If you do not find any loose connections and the 48 VDC power source is good, replace the fan.