Troubleshooting for invalid processes
Diagnostic code 716
Diagnostic code 716 occurs when there is a problem with the cut process sent to the Computer Numerical Control (CNC). There are six different smart-fault data values that you can get with a 716 code. The troubleshooting steps are different for the different values. When you get a 716 code, make sure that you identify the smart-fault value before you send a process change.
For an overview of the troubleshooting process for the 716 code, refer to Troubleshooting flowchart for diagnostic code 716.
Symptoms
| Code | Symptoms | XPR® models | XPR action | Code cancels with... |
|---|---|---|---|---|
| 716 |
The operator-selected process is not supported by this plasma cutting system. There are six smart-fault data values for the 716 code:
|
All models | None |
|
1: invalid id
The process ID is equal to zero (0).
2: invalid user
Another interface has control of the cutting system.
- Serial
- EtherCAT®
- Wireless
- Ethernet Local Area Network (LAN)
3: invalid user source
Another interface has control of the cutting system.
Only one wireless interface at a time can send a process ID to the plasma cutting system.
4: invalid process
An incorrect process ID was sent.
5: not allowed or system not ready
- Initial Checks state (2)
- Inert Gas Purge state (4)
- Wait for Start state (5)
- Manual Leak Test state (20)
- End of Cycle state (14)
6: not supported
The different gas connect consoles have different capabilities. For example, argon assist and argon marking for mild steel are available for cutting systems installed with OptiMix™, VWI™, or CorePlus™ gas connect consoles, but not with Core™.
This code can also occur when more amperage is necessary for the selected process than the cutting system can supply. For example, you can get this code if you select a 460 A process when you are using an XPR460® that has Chopper 3 disconnected or if you are using an XPR170® or XPR300®.