Diagnostic code 700
Diagnostic code 700 occurs because F5 gas inlet pressure in the gas connect console
is less than the permitted range. Do a check of the pressures and examine the gas
hoses and fittings.
Symptoms
| Code |
Symptoms |
XPR® models |
XPR action |
Code cancels with... |
| 700 |
The F5 inlet pressure (P6) in the gas connect console (only
for VWI™ or
OptiMix™) is less than
5.52 bar (80 psi) or more than 9.3 bar (135 psi). |
All models |
None |
- Set process
- Remote on-off
|
Corrective action
-
During test cutflow and test preflow, look at the Computer Numerical Control (CNC) or XPR web interface to identify the gas inlet pressure in the gas connect
console.
Look at the F5 inlet pressure (P6) for code 700.
-
Make sure that the gas inlet pressures inside of the gas connect
console are sufficient as specified in Permitted inlet pressures to gas connect consoles.
-
When gases are flowing and the pressure that you measured is not in the
permitted range, use the regulators to increase the pressure, if
necessary.
Do not exceed the recommended pressures.
-
If the pressure stays too low, examine the gas hoses and gas inlet
fittings for:
- Damage or kinks that can restrict flow
- Leaks that can decrease pressure
-
Replace the hoses if you find damage or kinks.
-
Put the hoses in a different position if you find kinks that can be
fixed.
-
Replace fittings that have damage.
-
Tighten loose connections if found.
-
If you cannot find
or correct the problem, speak to your cutting machine supplier or regional Hypertherm® Technical Service team.