Troubleshooting for a pilot arc timeout
Diagnostic code 521
Diagnostic code 521 identifies a problem with ignition of the plasma arc.
Symptoms
| Code | Symptoms | XPR® models | XPR action | Code cancels with... |
|---|---|---|---|---|
| 521 |
|
All models | End of cycle |
|
Corrective action
- Make sure that the work lead is connected to the workpiece.
- Make sure that the transfer height is correct.
- Examine the consumables.
- Replace consumables that have damage or excess wear.
Verification
Do a torch lead test. Refer to Do a test for continuity between the nozzle and workpiece.