Troubleshooting for gas mixture faults
Diagnostic codes 721 – 723, 726
Diagnostic codes 721–723 and 726 occur when there is a gas mixture failure.
Symptoms
| Code | Symptoms | XPR® models | XPR action | Code cancels with... |
|---|---|---|---|---|
| 721 | There was a failure of the mixing parameter checksum. (OptiMix™ only) | All models | Ramp down |
|
| 722 | There was a failure of the mixing flow calibration. (OptiMix only) | |||
| 723 | There was a failure of the mixing pressure calibration. (OptiMix only) | |||
| 726 | There is a problem with the mixing system clock. (OptiMix only) |
Corrective action
- Use the remote on-off switch to set the cutting system to OFF.
- Use the remote on-off switch to set the cutting system back to ON.
- Make sure that all of the wire harness connections for the gas mixer module are correct and are fully tightened.
-
If the diagnostic code continues: