Diagnostic code 691
Diagnostic code 691 occurs when the
main
control Printed Circuit Board (PCB) receives a
console reset message.
Symptoms
| Code |
Symptoms |
XPR® models |
XPR action |
Code cancels with... |
| 691 |
The main control PCB
receives a console reset message
after power is supplied to the plasma cutting system. |
All models |
Shut down |
Remote
on-off |
Corrective action
-
Examine the grounding for the cutting system.
High frequency Electromagnetic Interference (EMI) (also known
as noise) can reset the Controller Area Network (CAN)
node.
-
Make sure that the green power-indicator Light Emitting Diode (LED) on the gas connect console and on the
TorchConnect™ console is
illuminated.
-
If an LED is not illuminated,
examine the power distribution PCB and look for:
-
Loose and poorly connected connectors and CAN cables
-
Signs of 120 V (the D1 LED is illuminated)
-
If D1 is illuminated, examine the plasma power supply control
PCB.
-
Make sure that the remote on-off switch is in the ON position (enabled)
and the D89 LED is
illuminated.
If necessary, set the remote on-off switch to OFF and then back to
ON.
-
If you cannot find
or correct the problem, speak to your cutting machine supplier or regional Hypertherm® Technical Service team.
Make sure that you have the record ID for the error.