Troubleshooting for low fan speeds – MAGFAN
Diagnostic codes 744 – 746
Diagnostic codes 744 – 746 occur when a magnetics fan is under performing.
Symptoms
| Code | Symptoms | XPR® models | XPR action | Code cancels with... |
|---|---|---|---|---|
| 744 | The fan tachometer feedback for MAGFAN 1 is less than the minimum acceptable value. | All models | None |
|
| 745 | The fan tachometer feedback for MAGFAN 2 is less than the minimum acceptable value. | All models | None | |
| 746 | The fan tachometer feedback for MAGFAN 3 is less than the minimum acceptable value. | XPR460® | None |
Corrective action
- Use the Fan diagnostic codes diagram to identify the location of the MAGFAN in the plasma power supply.
-
Make sure that the following fan connections are good, and tighten loose
connections if found:
- The fan connector
- The wiring to J2 and J5 on the fan power distribution Printed Circuit Board (PCB)
- The wiring to J7 on the control PCB
- Examine the 48 VDC power source output.
- If the power output is not correct, replace the 48 VDC power source.
- Examine the solid-state relay, and make sure that it is operating correctly.
- If you do not find any loose connections and the 48 VDC power source and solid-state relay are good, replace the fan.