Diagnostic codes 752, 753, 754
Diagnostic codes 752 – 754 occur when there is a 3-phase error in a chopper.
Symptoms
| Code |
Symptoms |
XPR® models |
XPR action |
Code cancels with... |
| 752 |
There is a 3-phase error in Chopper 1. |
All models |
Shut down |
Remote on-off |
| 753 |
There is a 3-phase error in Chopper 2. |
XPR300®,
XPR460® |
| 754 |
There is a 3-phase error in Chopper 3. |
XPR460 |
Corrective action
-
Make sure that the input-line voltage is ±14% of nominal.
-
Remove the power from the cutting
system.
-
Remove the cover from the contactor.
-
Examine the contacts for excess wear, and replace the contactor if
necessary.
-
Examine the following contactor components for loose connections:
-
Contactor
-
Input to chopper
-
Power cord
-
Examine the phase conductors to the choppers for loose
connections.
-
Tighten loose connections if found.
-
If you cannot find