Diagnostic code 520
A 520 diagnostic code is an alert that shows after an ignition timeout when there is
no pilot arc.
Symptoms
| Code |
Symptoms |
XPR® models |
XPR action |
Code cancels with... |
| 520 |
The sensor in Chopper 1 does not measure current during the
600 millisecond ignite period because no current path completes
between the nozzle and the electrode. |
All models |
End of cycle |
- Start
- Set process
- Remote on-off
|
Corrective action
-
Make sure that the transfer height is correct and that the torch is not
in contact with the workpiece.
-
Examine the consumables, and replace any that have damage or excess
wear.
-
Make sure that the spark gap Printed Circuit Board (PCB)
is correctly connected to the ignition PCB.
-
Make sure that the spark gaps illuminate brightly.
-
If they do not, replace only the spark gap PCB.
-
Examine the main contactor:
-
Look for black or rough surfaces that are difficult to
remove.
-
Make sure that the contactor closes immediately after the Start
command is applied.
-
If the contactor is defective, replace it.
-
Examine the pilot-arc relay to make sure that it closes.
-
Examine the wiring to make sure that the coil receives 24 VDC.
-
Examine the start circuit PCB,
and replace it if it is defective.
-
Do a torch lead test: Do a test for continuity between the nozzle and workpiece.