Troubleshooting for low current
Diagnostic codes 550, 552 – 554
Diagnostic codes 550 and 552 – 554 identify a problem with a reduction in current in the plasma power supply.
Symptoms
| Code | Symptoms | XPR® models | XPR action | Code cancels with... |
|---|---|---|---|---|
| 550 | For a minimum of 10 milliseconds during a Steady state, the total current decreases to less than 50% of the current setpoint (setpoints can be different for different process types). | All models | End of cycle |
|
| 552 | The Chopper 1 current decreases to less than 50% of the setpoint for 50 milliseconds, and the setpoint is more than 10 A. | All models | End of cycle |
|
| 553 | The Chopper 2 current decreases to less than 50% of the setpoint for 50 milliseconds, and the setpoint is more than 10 A. | XPR300®, XPR460® | ||
| 554 | The Chopper 3 current decreases to less than 50% of the setpoint for 50 milliseconds, and the setpoint is more than 10 A. | XPR460 |