Troubleshooting for solenoid valve V1 in the TorchConnect console

Diagnostic code 730

This code occurs when there is a fault condition for valve V1 in the TorchConnect console.

Symptoms

Code Symptoms XPR® models XPR action Code cancels with...
730 There is a fault condition for receptacle valve V1 at the Printed Circuit Board (PCB) in the TorchConnect console. All models Ramp down
  • Set process
  • Remote on-off

Corrective action

  1. Examine the valve driver cable connections for the valve receptacle in the TorchConnect console.
  2. Replace the V1 valve if you find damage or excess wear.
  3. If the code continues, examine the leads, and make sure that the continuity in the leads is good.
  4. If the continuity is good and the code continues, replace the control PCB in the TorchConnect console.