Troubleshooting for solenoid valve V1 in the TorchConnect console
Diagnostic code 730
This code occurs when there is a fault condition for valve V1 in the TorchConnect™ console.
Symptoms
| Code | Symptoms | XPR® models | XPR action | Code cancels with... |
|---|---|---|---|---|
| 730 | There is a fault condition for receptacle valve V1 at the Printed Circuit Board (PCB) in the TorchConnect console. | All models | Ramp down |
|
Corrective action
- Examine the valve driver cable connections for the valve receptacle in the TorchConnect console.
- Replace the V1 valve if you find damage or excess wear.
- If the code continues, examine the leads, and make sure that the continuity in the leads is good.
- If the continuity is good and the code continues, replace the control PCB in the TorchConnect console.