Troubleshooting for pressure transducer faults
Diagnostic codes 706 – 715
Diagnostic codes 706 – 715 identify a problem with a pressure sensor in the TorchConnect™ console or the gas connect console.
Symptoms
| Code | Symptoms | XPR® models | XPR action | Code cancels with... |
|---|---|---|---|---|
| 706 | The P1 pressure sensor in the TorchConnect console is not found. | All models | Ramp down |
|
| 707 | The P2 pressure sensor in the TorchConnect console is not found. | |||
| 708 | The P3 pressure sensor in the TorchConnect console is not found. | |||
| 709 | The P4 pressure sensor in the TorchConnect console is not found. | |||
| 710 | The P5 pressure sensor in the TorchConnect console is not found. | |||
| 711 | The P14 pressure sensor in the TorchConnect console is not found. | |||
| 712 | The P6 pressure sensor in the gas connect console is not found. (VWI™ or OptiMix™ only) | |||
| 713 | The P7 pressure sensor in the gas connect console is not found. (VWI or OptiMix only) | |||
| 714 | The P8 pressure sensor in the gas connect console is not found. (VWI or OptiMix only) | |||
| 715 | The P9 pressure sensor in the gas connect console is not found. |