Troubleshooting for pressure transducer faults

Diagnostic codes 706 – 715

Diagnostic codes 706 – 715 identify a problem with a pressure sensor in the TorchConnect console or the gas connect console.

Symptoms

Code Symptoms XPR® models XPR action Code cancels with...
706 The P1 pressure sensor in the TorchConnect console is not found. All models Ramp down
  • Set process
  • Remote on-off
707 The P2 pressure sensor in the TorchConnect console is not found.
708 The P3 pressure sensor in the TorchConnect console is not found.
709 The P4 pressure sensor in the TorchConnect console is not found.
710 The P5 pressure sensor in the TorchConnect console is not found.
711 The P14 pressure sensor in the TorchConnect console is not found.
712 The P6 pressure sensor in the gas connect console is not found. (VWI or OptiMix only)
713 The P7 pressure sensor in the gas connect console is not found. (VWI or OptiMix only)
714 The P8 pressure sensor in the gas connect console is not found. (VWI or OptiMix only)
715 The P9 pressure sensor in the gas connect console is not found.

Corrective action

  1. Remove the power from the cutting system.
  2. Examine the pressure transducer for the diagnostic code that you see.
    For example:
    • If the code shows P1-TCC, examine the P1 pressure transducer in the TorchConnect console.
    • If the code shows P6-GCC, examine the P6 pressure transducer in the gas connect console.
  3. Make sure that the pressure transducer is correctly connected to:
    • TorchConnect console control Printed Circuit Board (PCB)
    • Gas connect console control PCB
  4. Install the pressure transducer correctly if you find loose or incorrect connections.
  5. If you find damage, replace the control PCB that has damage.
  6. Replace the pressure transducer.
  7. If you cannot find or correct the problem, speak to your cutting machine supplier or regional Hypertherm® Technical Service team.