Troubleshooting for pressure out is greater than pressure in
Diagnostic code 720
Diagnostic code 720 occurs when the output pressure is more than the input pressure on the mixer.
Symptoms
| Code | Symptoms | XPR® models | XPR action | Code cancels with... |
|---|---|---|---|---|
| 720 |
Pressure out (P21) is more than one of the pressures on the inlet side of the mixer (P10 – P12) by 0.069 bar (1 psi) or more. (OptiMix™ only) When this occurs, the mixer decreases flow to prevent backflow, which can have an effect on cut quality. |
All models | None |
|