Troubleshooting for manual-set mode faults
Diagnostic code 648
Diagnostic code 648 occurs when a condition stops manual-set mode. There are different smart-fault data values that you can get with a 648 code. The troubleshooting steps can be different for the different values. When you get a 648 code, make sure that you identify the smart-fault value before you start the troubleshooting steps.
Symptoms
| Code | Symptoms | XPR® models | XPR action | Code cancels with... |
|---|---|---|---|---|
| 648 |
Manual-set mode is stopped or was canceled. You can see these smart-fault data values with the 648
code:
|
All models | None |
|
1: Waiting for user input
The operator must start the manual-set mode process.
- Move the remote on-off switch from the ON position to the OFF position.
- Move the remove on-off switch from the OFF position back to the ON position.
2: Canceled: Firmware update
A firmware update stopped manual-set mode.
- Wait for the firmware update to complete.
- Set the power to the cutting system to OFF and then back to ON.
2: Canceled: Invalid configuration
The operator or process changed, or the system can no longer set the process that was saved before. For example, you can see this value if a chopper is disconnected or when the type of gas connect console changes.
- Use one of the usual processing setting methods to save a new process for the configuration.
2: Canceled: Set process
The operator has set the process. No steps are necessary.