Troubleshooting for high current

Diagnostic codes 555, 556, 557

Diagnostic codes 555 – 557 identify when the chopper current is too high.

Symptoms

Code Symptoms XPR® models XPR action Code cancels with...
555 For a minimum of 10 milliseconds, the electric current for Chopper 1 is more than 170 A. All models Shut down Remote on-off
556 For a minimum of 10 milliseconds, the electric current for Chopper 2 is more than 170 A. XPR300®, XPR460®
557 For a minimum of 10 milliseconds, the electric current for Chopper 3 is more than 170 A. XPR460

Corrective action

  1. Examine the consumables, and replace the consumables that have damage or excess wear.
  2. Do a test for gas leaks, and replace the leaking components if found.
  3. Examine the contactors, and replace the contactors that have damage, if found.
  4. Look for Direct Current (DC) bus errors.
  5. What system do you have? OptionDescription
    XPR170® Go to step 7.
    XPR300 or XPR460 Continue with the next step.
  6. Interchange the choppers and make sure that the diagnostic code aligns with the change:
    • If yes, the chopper is bad and must be replaced.
    • If no, continue with the next step.
  7. Examine the choppers and inductors.
  8. Replace choppers or inductors that have damage, if found.
  9. Make sure that the arc stays on the workpiece during cutting.
  10. If you cannot find or correct the problem, speak to your cutting machine supplier or regional Hypertherm® Technical Service team.