Diagnostic code 701
Diagnostic code 701 occurs because water inlet pressure in the gas connect console is
less than the permitted range. Do a check of the pressures, examine the water hoses
and fittings, and make sure that the shield water quality is good.
Symptoms
| Code |
Symptoms |
XPR® models |
XPR action |
Code cancels with... |
| 701 |
The water (H2O) inlet pressure (P8) in the gas
connect console (only for VWI™ or OptiMix™) is less than 2.07 bar (30
psi). |
All models |
None |
- Set process
- Remote on-off
|
Corrective action
-
During test cutflow and test preflow, look at the Computer Numerical Control (CNC) or XPR web interface to identify water inlet pressure in the gas connect
console.
Look at the H2O inlet pressure (P8) for code 701.
-
Make sure that the gas inlet pressures inside of the gas connect
console are sufficient as specified in Permitted inlet pressures to gas connect consoles.
-
Make sure that the water inlet pressure is at least 2.07 bar
(30
psi).
-
When water is flowing and the pressure that you measured is not in the
permitted range, use the regulators to increase the pressure, if
necessary.
Do not exceed the recommended pressures.
-
If the pressure stays too low, examine the gas hoses and gas inlet
fittings for:
- Damage or kinks that can restrict flow
- Leaks that can decrease pressure
-
Replace the hoses if you find damage or kinks.
-
Put the hoses in a different position if you find kinks that can be
fixed.
-
Replace fittings that have damage.
-
Tighten loose connections if found.
-
Make sure that the shield water quality is good.
-
If you cannot find
or correct the problem, speak to your cutting machine supplier or regional Hypertherm® Technical Service team.