Permitted inlet pressures to gas connect consoles
| Gas connect console | Permitted gas inlet pressures to the gas connect console | ||||
|---|---|---|---|---|---|
| H2 | N2 | Ar | F5 | H20 | |
| Core™ | – | 7.5 bar ± 0.4 (110 psi ± 5) | – | – | – |
| CorePlus™ | – | 7.5 bar ± 0.4 (110 psi ± 5) | 7.5 bar ± 0.4 (110 psi ± 5) | – | – |
| VWI™ | – | 7.5 bar ± 0.4 (110 psi ± 5) | 7.5 bar ± 0.4 (110 psi ± 5) | 7.5 bar ± 0.4 (110 psi ± 5) | 2.8 bar – 8.3 bar (40 psi – 120 psi) |
| OptiMix™ | 7.6 bar ± 0.4 (110 psi ± 5) | 7.6 bar ± 0.4 (110 psi ± 5) | 7.6 bar ± 0.4 (110 psi ± 5) | 7.9 bar ± 0.4 (115 psi ± 5) | 2.8 bar – 8.3 bar (40 psi – 120 psi) |