Troubleshooting for consumable part failure or no chopper current
Diagnostic codes 610 – 615 and 626 – 628
Diagnostic codes 610 – 615 identify a consumable part problem. Diagnostic codes 626 – 628 identify a condition when chopper current is not sufficient.
Symptoms
| Code | Symptoms | XPR® models | XPR action | Code cancels with... |
|---|---|---|---|---|
| 610 | A catastrophic failure of a consumable part is found on the Channel A Chopper 1 current signature. | All models | Ramp down | Remote on-off |
| 611 | A catastrophic failure of a consumable part is found on the Channel B Chopper 1 current signature. | All models | ||
| 612 | A catastrophic failure of a consumable part is found on the Channel A Chopper 2 current signature. | XPR300®, XPR460® | ||
| 613 | A catastrophic failure of a consumable part is found on the Channel B Chopper 2 current signature. | XPR300, XPR460 | ||
| 614 | A catastrophic failure of a consumable part is found on the Channel A Chopper 3 current signature. | XPR460 | ||
| 615 | A catastrophic failure of a consumable part is found on the Channel B Chopper 3 current signature. | XPR460 | ||
| 626 |
For a minimum of 250 milliseconds after the Arc-on state starts, Chopper 1 does not make current. |
All models | End of cycle |
|
| 627 | For a minimum of 250 milliseconds after the Arc-on state starts, Chopper 2 does not make current. | XPR300, XPR460 | ||
| 628 | For a minimum of 250 milliseconds after the Arc-on state starts, Chopper 3 does not make current. | XPR460 |
Corrective action
- Examine the consumable parts for damage and excess wear.
- If a consumable part must be replaced, refer to Install the consumables.
- If you cannot find or correct the problem, speak to your cutting machine supplier or regional Hypertherm® Technical Service team.